System Capacity
Extension
Total Number of Extensions (DXDP) 104.0
IP Proprietary Telephone (IP-PT) - MPR 64.0
SIP Telephone - MPR 64.0
Single Line Telephone (SLT) 36.0
Digital Proprietary Telephone (DPT) with DXDP 36.0
DPT and SLT with DXDP 40.0
Trunk
Total Number of Trunks 96.0
SIP Trunks - MPR 32.0
H.323 - MPR 32.0
PSTN Analogue Trunks 16.0
ISDN - BRI 16 (8BRI)
ISDN - PRI30 60 (2PRI)
PSTN and ISDN 64.0
PS
DECT Wireless Handsets 64.0
CS
DECT Cell Station (DPTI/F) 8.0
High Density DECT Cell Station 4.0
Specifications
Control Bus Original bus (16-bit, 8 MHz, 10megabytes per second)
Communication Bus H.100 bus conformity (1024 time slots)
Power Input 100 V AC to 130 V AC; 1.0 A / 200 V AC to 240 V AC; 0.5 A / 50 Hz/60 Hz
Power Consumption 65 W
Maximum Power Failure Tolerance 300 ms
Memory Backup Duration 7 years
Dialling
Trunk Dial Pulse (DP) 10 pps, 20 pps Tone (DTMF) Dialling
Extension Dial Pulse (DP) 10 pps, 20 pps Tone (DTMF) Dialling
Mode Conversion DP-DTMF, DTMF-DP
Ring Frequency 20 Hz/25Hz (Selectable)
Trunk Loop Limit 1600 Ohm Maximum
Operating Environment
Temperature (°C) 0-40 °C
Temperature (°F) 32-104 °F
Humidity (%) 10 - 90 % (non-condensing)
Conference Call Trunk From 10 x 3-Party Conference Call to 4 x 8-Party Conference Call
Paging
Internal Level Control: -6 dB to +3 dB steps in 3 dB steps
External 1 port (Volume Control: -15 dB to +6 dB in 3 dB steps)
RJ45 Port
MNT Port 1 (for PC connection)
LAN Port 1 (for LAN connection)
Connection Cable
Trunk RJ45, BNC
Extension RJ45
Paging Output 1 conductor jack
External Voice Input 1 conductor jack
PT-Interface CS RJ45
Music on Hold
Number of Ports 1.0
Support for External Music Source yes
Connectors
CO Line RJ45, BCN
Station RJ45
Paging Output 1 Conductor Jack
External Voice Output 1 Conductor Jack
RS232CSMDR Outputs RS232, LAN
USB Ports no
Ethernet RJ45 yes
Features
System
Tenant 8.0
Class of Service 64.0
Trunk Group 64.0
Paging Group 32.0
Call Pickup Group 64.0
Incoming Call Distribution (ICD) Group 128 (32 extensions/group)
Portable station (PS) Ring Group 32.0
Voice Mail (DPT) Group 2 groups x 12 ports (24 channels)
Queuing Time Table 64.0
Idle Extension Hunting Group 64 (16 extensions/group)
Absent Message Extension 1 x 16 characters
Absent Message System 8 x 16 characters
Message Waiting - PT + SLT 512.0
Number of the characters of Name 20.0
Extension Number Digits 10 digits, 1 entry/extension
Call Park Zone 100.0
Conference 3-8 parties per conference (32 parties total)
Special Carrier Code 16 digits, 20 entries
Verified Code 4 digits, 1,000 entries
Verified Code Personal Identification Number (PIN) 10 digits, 1,000 entries
Host PBX Access Code 10 digits, 10 entries/trunk group
DDI/DID Table 32 digits, 1,000 entries
Station Message Detailed Recording (SMDR) Call Storage 200 calls
Dialling
Emergency Call 32 digits, 10 entries
Quick Dialling 8 digits, 4,080 entries
System Speed Dialling 32 digits, 1,000 entries/tenant
Personal Speed Dialling 32 digits, 100 entries/extn.
One-Touch Dialling 32 digits
Hot Line 32 digits
Key Pad Protocol Dial (ISDN Service Access) 32 digits
Redial 32 digits
Toll Restriction / Barring
Toll Restriction/Barring Level 7.0
Toll Restriction /Barring Denied Code 16 digits, 100 entries/level
Toll Restriction /Barring Exception Code 16 digits, 100 entries/level
Automatic Route Selection (ARS)
Routing Plan Table 16 entries
Leading Number Table 16 digits, 1,000 entries
Leading Number Exception Table 16 digits, 200 entries
ARS Carrier 10.0
Itemised Billing Code 10 digits
Authorisation Code 10 digits
Call Log
Outgoing Call Log - PT 100 records/extn. 1,520 records/system
Outgoing Call Log - PS 100 records/extn. 640 records/system
Networking
TIE Routing Table 32 entries
Leading Number 3 digits
PBX Code 7 digits
Password
System Password for Administrator - PC Programming 4 - 10 characters
System Password for User - PC Programming 4 - 10 characters
System Password for User - PT Programming 4 - 10 digits
System Password for Administrator - PT Programming 4 - 10 digits
Manager Password 4 - 10 digits
Extension Personal Identification Number (PIN) 1 - 5 digits (1 - 4 digits for PSs, 2 - 4 digits for extensions which have a VM (DPT) mailbox)
General Data
Dimensions (mm)
Width 430mm
Height 128mm
Depth 340mm
Weight (when fully mounted) 7.5kg